Product Details

Loop capacity 235 addresses loop 1 can be expanded to 2 loops
8×18 Graphical LCD Display
30 Zone indication including manual intervention and control
3 programmable alarm output
Positive Alarm Signal (PAS) Pre-alarm
Maintenance report of dirty detector
Networkable with all SHIELD Intelligent Fire Alarm panels
Programmable form PC by SHIELD
History log 999-events capacity in non-volatile memory
Test facility
RS485 Repeater Output (Max. 10)
Built-in gas extinguishing control.
Advanced user friendly programming software including ‘Fuzzy Logic’
Optional Colour Graphics
Optional Fireman’s Control Panel
Optional Panel Printer

Product Details

8 x Loops (242) capacity (1936) addressable points
Max 10 Loops Standalone
Comply with EN54 and UL864
Modular constructed for future expansion
40 x15 lines Colour Graphical LCD Display
Up to 999 programmable zones and 140 Zone indication
Networked with all SHIELD Intelligent Fire panels up to 64 Nodes, Optional Fiber Optic and LAN Network Interface.
RS 485 mimic and repeater output up 64
RS 232-USB CRT interface, including P-CGS graphic
History record-999 fire incident only and 999 event capacity in non-volatile memory
Online/Offline Programmable form PC
Walk Test Function with optional silent mode
Fully simulation of Cause and Effect
Advanced user friendly programming software including ‘Fuzzy Logic’.
Built in Fire Alarm, FPE, Fault and Alarm Router output
Auto Programming Day and Night Mode
Enable and Disable function
Pre-Alarm and Acknowledge Function
Duplicate address checking
Device mismatch
Dirty Detector Reporting
Panel Printer included
Built in Battery charger

Product Details

Build-in microprocessor
Self-diagnosis function can monitor the inner fault.
Built-in relay contacts for control Gas Valve/Extract etc
Built-in Sounder
Manual reset and control of relays contact
Electronically addressed
Wall mounting. Easy installation and connection
Available in Natural Gas (NG), LPG and Coal Gas

Product Details

Providing two pairs of input signals, working mode can be set normally open and normally
closed through a programmer. Input signals are separated from the loop.
Providing two pairs of output contact signals, it can carry out voltage output through external
circuit.
Occupying two consecutive addresses. They can be modified through a programmer or fire alarm
control panel (FACP).
Monitoring power supply
Plug-in structure

Product Details

Twin LED for 360° view.
Electronically addressed in field.
Built-in microprocessor stores 14 history data.
Rate of rise and fixed temperature alarm modes.
Self-diagnostic.
Remote indicator output available.
Complies with EN 54-5 standard.

Contact us about Heat Detector:

Product Details

Polarity-sensitive external connections. Input and output can be used inversely without direction.
Delayed power-up to output end devices, avoids strong transient current when the load is heavy.
Plug-in structure.

Product Details

Electronically addressed. The address can be modified in field.
Alarming by pressing. Reset by a special key.
Plug-in structure.
Designed to comply with EN 54-11.

Product Details

Electronically addressed.
Built-in microprocessor stores 14 history data.
Drift compensation, adaptable to environment extensively.
Combined smoke and heat algorithm greatly improves detector performance.
Self-diagnostic.
Dirty chamber checking.
Designed to comply with EN 54-5/EN 54-7 standards.

Product Details

Twin LED for 360° view.
Electronically addressed in field.
Built-in microprocessor stores 14 history data.
Drift compensation to suit environment changing extensively.
Self-diagnostic.
Remote indicator output available.
Complies with EN 54-7 standard.

Product Details

Providing two tones.
Using several high red LEDs as light source.
Initiated by shorting external terminals; not affected by loop power cut.
Signal loop and power loop are polarity-insensitive, which is convenient for wiring and features power-off checking.
Standard: EN 54-3.

Product Details

The built-in microprocessor can conduct the signals and communicate with fire alarm control panel (FACP).
With algorithm, report alarm quickly and reduce false alarm rate.
Three sensitivity levels.
High sensitivity, reliable performance, dust-proof, damp-proof and corrosion-proof.

Product Details

Providing two tones.
Initiated by shorting external terminals, not affected by loop power cut.
Polarity insensitive signal loop and power loop, with features of cable checking in case
of power cut.

Contact us about Sounder:

Product Details

Non polarized terminals Multi- positioning designs allows easy direction adjustment of
the detectors
Compatible with SHIELD conventional detectors using 4k7 Ohms resistor